Chapter 3: AT Commands Reference
April 15, 2008 G24-L AT Commands Reference Manual 3-171
OK
AT+MADIGITAL=0
OK
AT+MADIGITAL?
+MADIGITAL: 0
OK
AT+MADIGITAL=3
ERROR
AT+MADIGITAL?
+MADIGITAL: 0
OK
+CALM, Alert Sound Mode
This command handles the selection of the G24-L's alert sound mode. The value of the command
is saved after a power cycle.
The following table shows the +CALM parameters.
Note: Selecting the ring mode with this command retrieves the current alert volume level
setting.
Example
AT+CALM=?
+CALM: (0,1)
OK
AT+CALM?
+CALM: 0
OK
AT+CALM=1
OK
Command Type Syntax Response/Action Remarks
Set
+CALM=<mode> OK
+CME ERROR: <err>
The Set command sets the alert sound
mode.
Read
+CALM? +CALM: <mode>
+CME ERROR: <err>
The Read command displays the
current alert sound mode setting.
Test
+CALM=? +CALM: (list of
supported <mode>s)
+CME ERROR: <err>
The Test command displays the list of
supported modes.
Table 3-113: +CALM Parameters
<Parameter> Description
<mode> Alert sound mode of the G24-L.
0 Ring (default)
1 Silent mode (ring prevented)
Vue de la page 234